Flash point testing

Setaflash Series 3 High Temperature

Flash point tester, semi-automatic, closed cup, RT up to 300 °C

Technical Data

Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min under 100°C, 2 min over 100°C
Test Method: Ramp Mode
Ramp Rate: up to 6 °C/min
Dimensions (W x D x H): 295 x 195 x 140 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 Active Cool

Flashpoint tester, semi-automatic, closed cup, 10 °C to 135 °C

Technical Data

Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min below 100°C, 2 min over 100°C
Test Method: Equilibrium and Ramp method
Ramp Rate: 2°C/ min
Temperature Control: Peltier cooling
Dimensions (W x D x H): 295 x 140 x 195 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 (Open Cup)

Flash point tester, semi-automatic, open cup

Technical Data

Temperature Range: RT to 300 °C
Sample Volume: 2 ml
Test Duration: 1 min below 100 °C, 2 min between 100 °C and 300 °C
Test Method: Equilibrium method
Dimensions (W x D x H): 280 x 256 x 256 mm
Weight: 4 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 8 High Temperature

Flashpoint tester, automatic, RT up to 300 °C

Technical Data

Temperature Range: RT to 300 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Ceramic heating plate and fan
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 8 Active Cool

Flashpoint tester, automatic, -30 °C to 135 °C

Technical Data

Temperature Range: -30 °C to 135 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Peltier cooling
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Cleveland Flash point tester, automatic

Automatic determination of flash and fire points of petrochemical products according to the Cleveland Open Cup (COC) test method

Technical Data

Dimensions (L x W x H): 240 x 385 x 450 mm
Weight: 15.5 kg
Mains: 100 V to 240 V, 47 Hz to 63 Hz, autosensing
Cooling: Fast forced air (ingetral fan, adjustable)

DetailviewDatasheet as PDFQuestions?

Cleveland Flashpoint, semi-automatic

Semi-automatic determination of flash and fire point of petrochemical products according to Cleveland Open Cup (COC) test method

Technical Data

Temperature Range: RT to 370 °C
Dimensions (H x W x D): 32 x 31 x 29 cm
Weight: 6.5 kg
Mains: single-phase, 220/240 V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Pensky Martens Flashpoint, automatic

Automatic determination of the flash point of petrochemical products according to the Pensky Martens test method in a closed cup

Technical Data

Temperature Range: RT to 400 °C
Dimensions (H x W x D): 38.5 x 24 x 50 cm
Weight: 25 kg
Mains: single-phase, 230V +/-15% or 110V +/-15%, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Pensky Martens Flashpoint, semi-automatic

semi-automatic determination of the flash point of petrochemical products according to the Pensky Martens test method in a closed cup

Technical Data

Temperature Range: RT to 370 °C
Dimensions (H x W x D): 280 x 350 x 250 mm
Weight: approx. 8 kg
Mains: single-phase, 110/120V , 60 Hz, 220/240V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

TAG Flash Point Tester, semi-automatic

semi-automatic determination of the flash point of petrochemical products according to TAG test method in a closed cup

Technical Data

Temperature Range: RT to 93 °C
Dimensions (H x W x D): 33 x 31 x 29 cm
Weight: 5 kg
Mains: 110/120 V, 50/60 Hz 220/240 V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?