Flash point testing
Setaflash Series 3 High Temperature
Flash point tester, semi-automatic, closed cup, RT up to 300 °C
Technical Data
Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min under 100°C, 2 min over 100°C
Test Method: Ramp Mode
Ramp Rate: up to 6 °C/min
Dimensions (W x D x H): 295 x 195 x 140 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz
Setaflash Series 3 Active Cool
Flashpoint tester, semi-automatic, closed cup, 10 °C to 135 °C
Technical Data
Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min below 100°C, 2 min over 100°C
Test Method: Equilibrium and Ramp method
Ramp Rate: 2°C/ min
Temperature Control: Peltier cooling
Dimensions (W x D x H): 295 x 140 x 195 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz
Setaflash Series 3 (Open Cup)
Flash point tester, semi-automatic, open cup
Technical Data
Temperature Range: RT to 300 °C
Sample Volume: 2 ml
Test Duration: 1 min below 100 °C, 2 min between 100 °C and 300 °C
Test Method: Equilibrium method
Dimensions (W x D x H): 280 x 256 x 256 mm
Weight: 4 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz
Setaflash Series 8 High Temperature
Flashpoint tester, automatic, RT up to 300 °C
Technical Data
Temperature Range: RT to 300 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Ceramic heating plate and fan
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz
Setaflash Series 8 Active Cool
Flashpoint tester, automatic, -30 °C to 135 °C
Technical Data
Temperature Range: -30 °C to 135 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Peltier cooling
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz
Cleveland Flash point tester, automatic
Automatic determination of flash and fire points of petrochemical products according to the Cleveland Open Cup (COC) test method
Technical Data
Dimensions (L x W x H): 240 x 385 x 450 mm
Weight: 15.5 kg
Mains: 100 V to 240 V, 47 Hz to 63 Hz, autosensing
Cooling: Fast forced air (ingetral fan, adjustable)
Cleveland Flashpoint, semi-automatic
Semi-automatic determination of flash and fire point of petrochemical products according to Cleveland Open Cup (COC) test method
Technical Data
Temperature Range: RT to 370 °C
Dimensions (H x W x D): 32 x 31 x 29 cm
Weight: 6.5 kg
Mains: single-phase, 220/240 V, 50/60 Hz
Pensky Martens Flashpoint, automatic
Automatic determination of the flash point of petrochemical products according to the Pensky Martens test method in a closed cup
Technical Data
Temperature Range: RT to 400 °C
Dimensions (H x W x D): 38.5 x 24 x 50 cm
Weight: 25 kg
Mains: single-phase, 230V +/-15% or 110V +/-15%, 50/60 Hz
Pensky Martens Flashpoint, semi-automatic
semi-automatic determination of the flash point of petrochemical products according to the Pensky Martens test method in a closed cup
Technical Data
Temperature Range: RT to 370 °C
Dimensions (H x W x D): 280 x 350 x 250 mm
Weight: approx. 8 kg
Mains: single-phase, 110/120V , 60 Hz, 220/240V, 50/60 Hz
TAG Flash Point Tester, semi-automatic
semi-automatic determination of the flash point of petrochemical products according to TAG test method in a closed cup
Technical Data
Temperature Range: RT to 93 °C
Dimensions (H x W x D): 33 x 31 x 29 cm
Weight: 5 kg
Mains: 110/120 V, 50/60 Hz 220/240 V, 50/60 Hz