Surfaces and coatings
Extrusion Plastometer MFR/MVR (Melt Flow Index Tester)
Device for MFI-measurement of meltmass flow rate and melt-volume flow rate
Pourability
Funnel for measurement of the pourability of free flow powder or granulate
Technical Data
Funnel: Ø 110 mm, 40° angle
Dimensions (W x D x H): 290 x 160 x 210 mm
Weight: approx. 7.5 kg
Bulk Density / Apparent Density
Funnel for measurement of the apparent density of free flow powder or granulate according to above listed standards
Technical Data
Funnel: Height: 115 mm, volume approx. 200 ml
Measuring cup: 100 ±0.5 m
Dimensions (W x D x H): 260 x 160 x 210 mm
Weight: ca. 3.5 kg
Pourability and bulk density
Combined system to measure both pourability and apparent/bulk density.
Technical Data
Funnel: Ø 110 mm, 40° angle
Dimensions (W x D x H): 290 x 160 x 210 mm
Weight: approx. 8 kg
Bulk Density ASTM D1895
3 models for determination of bulk density acc. to ASTM D 1895 Method A, Method B or Method C
Universal Testing Machine (one column)
Small and economical UTM up to 5 kN test load
Technical Data
Force: 3 kN, 5 kN
Speed: 1-700 mm/min
Crosshead-distance: 66-500 mm or 66-1200 mm
Universal Testing Machine (two columns)
Universal tensile, compression and flexure testing machine with 10 kN, 20 kN and 50 kN test force, different stroke lengths and light ranges with various accessories.
Technical Data
Force: 10 kN, 20 kN, 50 kN
Speed: 1-600 mm/min or 0.03 209 mm/min
Crosshead-distance: 700 or 1200 mm
Column-distance: 400-800 mm or 420 mm
Tracking Current Tester
The device is used to determine the tracking resistance of solid electrical insulation materials according to DIN EN 60 112 / IEC 60 112 / resp. VDE 0303 Teil 1.
Technical Data
Test voltage: 0 V to 600 V adjustable
Dimensions (W x H x D): Control unit: 610 x 305 x 600 mm / Test unit: 610 x 550 x 450 mm
Weight: Control unit: approx. 35 kg / Test unit: approx. 35 kg
Mains: 230 V
Glow wire flammability test
Test device for determining the glow wire flammability index (GWFI), the glow wire ignition temperature (GWIT), and the glow wire temperature (GWT).
Technical Data
Glow wire temperature range: 100 to 999 °C
Dimensions (W x H x D): 570 x 550 x 340 mm
Weight: approx. 27 kg
Mains: 230 V
Cathodic Disbondment (CD-Tester)
The CD-Test unit tests the adhesion of plastic coatings on steel.
Technical Data
Measuring stations: 1 / 4 / 8 / 10 / 16 / 20 / 30 (depending on configuration)
Voltage: 5 V
max. current: ± 200 mA
Current ranges: 200 mA
Dimensinos (H x W x D): 152 x 280 x 385 mm (4-place) / 152 x 560 x 385 mm (8-place) / 304 x 560 x 385 mm (16-place)
Weight: 6 / 12 / 18 kg (depending on configuration)
Mains: 230 V / 50 – 60 Hz oder 110 V / 50 – 60 Hz