Mineral oil products (Stanhope Seta)

Stanhope Seta Catalogue

We represent Stanhope Seta in Germany and supply equipment and accessories. Furthermore, you can get in touch with us for maintenance and calibration.

DetailviewQuestions?

Manual Penetrometer

Manual penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Measuring Range: 0-360 PEN
Resolution: 1 PEN (0.1 mm)

DetailviewDatasheet as PDFQuestions?

Semi-automatic Penetrometer

Semi-automatic penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Measuring Range: 0-360 PEN
Resolution: 1 PEN (0.1 mm)

DetailviewDatasheet as PDFQuestions?

Digital semi-automatic Penetrometer

Digital, semi-automatic penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Display: digital
Measuring Range: 0-63 mm
Resolution: 0.01 mm
Penetration Time: 5, 8, 10, 12, 30, 60 Seconds selectable
Dimensions (W x D x H): 300 x 330 x 530 mm
Weight: 8.3 kg
Mains: 220/240 V and 110/120V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Digital automatic Penetrometer

Digital, automatic penetrometer with microcontroller and surface detector for determining the deformability (flowability/consistency) of plastic and elastic masses (greases, ointments, creams, pastes, bitumen)

Technical Data

Masuring Range: 0-300 PEN (corresponds to 0-30 mm)
Resolution: 0.01 mm
Penetration Time: freely adjustable from 0,01 s
Dimensions (W x D x H): 280 x 490 x 760 mm
Weight: 26 kg
Mains: 100/240 V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 High Temperature

Flash point tester, semi-automatic, closed cup, RT up to 300 °C

Technical Data

Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min under 100°C, 2 min over 100°C
Test Method: Ramp Mode
Ramp Rate: up to 6 °C/min
Dimensions (W x D x H): 295 x 195 x 140 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 Active Cool

Flashpoint tester, semi-automatic, closed cup, 10 °C to 135 °C

Technical Data

Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min below 100°C, 2 min over 100°C
Test Method: Equilibrium and Ramp method
Ramp Rate: 2°C/ min
Temperature Control: Peltier cooling
Dimensions (W x D x H): 295 x 140 x 195 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 (Open Cup)

Flash point tester, semi-automatic, open cup

Technical Data

Temperature Range: RT to 300 °C
Sample Volume: 2 ml
Test Duration: 1 min below 100 °C, 2 min between 100 °C and 300 °C
Test Method: Equilibrium method
Dimensions (W x D x H): 280 x 256 x 256 mm
Weight: 4 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 8 High Temperature

Flashpoint tester, automatic, RT up to 300 °C

Technical Data

Temperature Range: RT to 300 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Ceramic heating plate and fan
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 8 Active Cool

Flashpoint tester, automatic, -30 °C to 135 °C

Technical Data

Temperature Range: -30 °C to 135 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Peltier cooling
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?