Mineral oil products

Manual Penetrometer

Manual penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Measuring Range: 0-360 PEN
Resolution: 1 PEN (0.1 mm)

DetailviewDatasheet as PDFQuestions?

Semi-automatic Penetrometer

Semi-automatic penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Measuring Range: 0-360 PEN
Resolution: 1 PEN (0.1 mm)

DetailviewDatasheet as PDFQuestions?

Digital Penetrometer SETAMATIC

Digital penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Display: digital - mm or PEN
Mesauring Range: 0-63 mm or 0-630 PEN
Resolution: 0,1 mm oder 1 PEN
Penetration Time: 1-9999 s
Dimensions (W x D x H): 300 x 330 x 590 mm
Weight: 12.5 kg
Mains: 220/240 V, 50/60 Hz or 110/120V (switchable)

DetailviewDatasheet as PDFQuestions?

Digital semi-automatic Penetrometer

Digital, semi-automatic penetrometer for determining the deformability (flowability/consistency) of plastic and elastic masses (lubricating greases, ointments, creams, pastes, bitumen) using penetration measurement

Technical Data

Display: digital
Measuring Range: 0-63 mm
Resolution: 0.01 mm
Penetration Time: 5, 8, 10, 12, 30, 60 Seconds selectable
Dimensions (W x D x H): 300 x 330 x 530 mm
Weight: 8.3 kg
Mains: 220/240 V and 110/120V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Digital automatic Penetrometer

Digital, automatic penetrometer with microcontroller and surface detector for determining the deformability (flowability/consistency) of plastic and elastic masses (greases, ointments, creams, pastes, bitumen)

Technical Data

Masuring Range: 0-300 PEN (corresponds to 0-30 mm)
Resolution: 0.01 mm
Penetration Time: freely adjustable from 0,01 s
Dimensions (W x D x H): 280 x 490 x 760 mm
Weight: 26 kg
Mains: 100/240 V, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 High Temperature

Flash point tester, semi-automatic, closed cup, RT up to 300 °C

Technical Data

Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min under 100°C, 2 min over 100°C
Test Method: Ramp Mode
Ramp Rate: up to 6 °C/min
Dimensions (W x D x H): 295 x 195 x 140 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 Active Cool

Flashpoint tester, semi-automatic, closed cup, 10 °C to 135 °C

Technical Data

Temperature Range: 10 °C to 135 °C
Sample Volume: 2ml or 4ml
Test Duration: 1 min below 100°C, 2 min over 100°C
Test Method: Equilibrium and Ramp method
Ramp Rate: 2°C/ min
Temperature Control: Peltier cooling
Dimensions (W x D x H): 295 x 140 x 195 mm
Weight: 3 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 3 (Open Cup)

Flash point tester, semi-automatic, open cup

Technical Data

Temperature Range: RT to 300 °C
Sample Volume: 2 ml
Test Duration: 1 min below 100 °C, 2 min between 100 °C and 300 °C
Test Method: Equilibrium method
Dimensions (W x D x H): 280 x 256 x 256 mm
Weight: 4 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 8 High Temperature

Flashpoint tester, automatic, RT up to 300 °C

Technical Data

Temperature Range: RT to 300 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Ceramic heating plate and fan
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz

DetailviewDatasheet as PDFQuestions?

Setaflash Series 8 Active Cool

Flashpoint tester, automatic, -30 °C to 135 °C

Technical Data

Temperature Range: -30 °C to 135 °C
Sample Volume: 2 ml or 4 ml
Ramp Rate: up to 10 °C/min
Temperature Control: Peltier cooling
Dimensions (H x W x D): 300 x 340 x 380 mm
Weight: 8 kg
Mains: single-phase, 110/120V or 220/240V switchable, 50/60 Hz