VICAT/ HDT
NEW: VST/ HDT Safety Housing
Optional Housing for VST/ HDT Basic 3 / Standard 6 / Standard 6
Technical Data
Front Door: Electrically locked
Housing: PMMA
VST/HDT Compact 3/6 (discontinued model)
Compact VICAT and HDT device with 3 or 6 measuring stations
Technical Data
Temperature: +30 °C to +300°C
Digital displacement transducer, resolution: 0.001 mm
Cooling connection: 1/2 ''
Dimensions 3 station device (W x D x H): 600x 600 x 470 mm
Dimensions 6 station device (W x D x H): 720 x 660 x 470 mm
Weight: approx. 60 kg
Mains: 230 V, 50/60 Hz, 3200 VA
VST/HDT Basic 2/3 (discontinued model)
Three station machine for small measuring batches and ideal for teaching purposes due to manual test set up
Technical Data
Temperature: +30 °C to +300 °C
Digital displacement gauges, resolution: 0.001 mm
Cooling connection: 1/2 ''
Dimensions (W x D x H): 500 x 580 x 480 mm
Weight: 31 kg
Mains: 230 V, 50/60 Hz, 2000 VA
VST ECO Oilfree 3/6
Oilfree VICAT measuring device with 3 or 6 stations
Technical Data
Temperature: +30 °C to +300 °C
Displacement transducer, resolution: 0.001 mm
Cooling connection: 1/2 ''
Integrated weight set: 10 N and 50 N
Dimensions (W x D x H): 400 x 750 x 700 mm
Weight: approx. 60 kg
Compressed air: 5-10 bar
Mains: 230 V, 50/60 Hz, 800 VA
NEW: VST/ HDT Standard 6
Compact Tabe-Top Unit with 6 Stations for industrial HDT and VST measurement
Technical Data
Temperature: 20 to 300 °C (optional up to +350 °C)
Travel Resolution: 0,001 mm
Bathvolume: 11,5 l
Cooling Time (300 °C -> RT): ~ 40 min (optional <15 min)
Dimensions H x D x W: 790 x 560 x 1040 mm
Weight: 70 kg
Mains: 230 V, 50 Hz, 3200 W
NEW: VST/ HDT Standard 3
Compact Tabe-Top Unit with 3 Stations for industrial HDT and VST measurement
Technical Data
Temperature: 20 to 300 °C (optional up to 350°C)
Travel Resolution: 0,001 mm
Bathvolume: 7 l
Cooling Time (300 °C -> RT): ~ 40 min (optional <15 min)
Dimensions H x D x W: 790 x 560 x 800 mm
Weight: 70 kg
Mains: 230 V, 50 Hz, 3200 W
NEW: VST/ HDT Basic 3
Economic VICAT und HDT Messgerät with 3 Stations
Technical Data
Temperature: 20 to 300 °C (optional up to 350 °C)
Travel Resolution: 0,001 mm
Bathvolume: 7 l
Cooling Time (300 °C -> RT): ~40 min (optional <15 min)
Dimensions H x D x W: 790 x 560 x 800
Weight: 70 kg
Mains: 230 V, 50 Hz, 3200 W
NEW: VST/ HDT Semi-Automatic 6
Semi-Automatic VST and HDT Tester with 6 stations
Technical Data
Temperature: 20 to300 °C (optional up to 350°C)
Travel Resolution: 0,001 mm
Bathvolume: 11,5 l
Cooling Time (300 °C -> RT): ~40 min (optional <15 min)
Dimensiones H x D x W: 810 x 470 x 1.040 mm
Weight: 100 kg
Mains: 230 V, 50 Hz, 3200 W
NEW: HDT Automat 6
Fully automated HDT tester with sample feeder
Technical Data
Temperature: 20 to300 °C (optional up to 350°C)
Travel Resolution: 0.001 mm
Bathvolume: 11.5 Liter
Cooling Time (300 °C -> RT): ~40 min (optional <15 min)
Dimensions H x D x W: 1.000 x 736 x 1.600 mm
Weight: 150 kg
Mains: 230 V, 50 Hz, 3200 W